This site uses cookies

By using this site you agree to the use of cookies for analytics and personalized content.

X

Leister Europe

Leister Amerikas

Leister Asia and Oceania

Leister Africa and Middle East

  • Albania | EN
  • Andorra | ES / FR / EN
  • Armenia | EN
  • Azerbaijan | EN
  • Belarus | EN
  • Belgium | NL / FR / EN
  • Bosnia - Herzegovina | EN
  • Bulgaria | EN
  • Croatia | EN / DE
  • Cyprus | EN
  • Czech Republic | EN / DE
  • Denmark | EN
  • Estonia | EN
  • Faeroe Islands | EN
  • Finland | EN
  • France | FR / EN / DE
  • Georgia | EN
  • Germany | DE / EN
  • Gibraltar | EN
  • United Kingdom | EN
  • Greece | EN
  • Hungary | EN / DE
  • Iceland | EN
  • Ireland | EN
  • Italy | IT / EN
  • Kosovo | EN
  • Latvia | EN
  • Lithuania | EN
  • Luxembourg | DE / FR / EN
  • Macedonia | EN
  • Malta | IT / EN
  • Moldova | EN
  • Monaco | FR / IT / EN
  • Montenegro | EN
  • Netherlands | NL / EN
  • Norway | EN
  • Austria | DE / EN
  • Poland | DE / EN
  • Portugal | EN / ES
  • Liechtenstein | DE
  • Romania | EN
  • Russia | EN
  • San Marino | IT / EN
  • Serbia | EN
  • Slovakia | EN / DE
  • Slovenia | EN / DE
  • Spain | ES / EN
  • Sweden | EN
  • Switzerland | DE / FR / IT / EN
  • Turkey | EN
  • Ukraine | EN
  • Vatican | IT / EN
  • Anguilla | EN
  • Antigua & Barbuda | EN
  • Argentinia | ES / EN / DE
  • Aruba | EN / NL / ES
  • Bahamas | EN
  • Barbados | EN
  • Belize | ES / EN
  • Bolivia | ES / EN
  • Brazil | EN / ES
  • Canada | EN / FR
  • Caribbean Netherlands | EN / NL
  • Cayman Islands | EN
  • Chile | ES / EN
  • Colombia | ES / EN
  • Costa Rica | ES / EN
  • Cuba | ES / EN
  • Curaçao | EN / NL
  • Turks & Caicos Islands | EN
  • Dominican Republic | ES / EN
  • Ecuador | ES / EN
  • El Salvador | ES / EN
  • Grenada | EN
  • Guadeloupe | EN / FR
  • Guatemala | ES / EN
  • Haiti | ES / EN
  • Honduras | ES / EN
  • Jamaica | EN
  • Martinique | EN / FR
  • Mexico | ES / EN
  • Montserrat | EN
  • Nicaragua | ES / EN
  • Panama | ES / EN
  • Peru | ES / EN
  • Puerto Rico | ES / EN / DE
  • Saint Barthélemy | EN / FR
  • Saint Kitts & Nevis | EN
  • Saint Lucia | EN
  • Saint Martin | EN / FR
  • Saint Vincent & Grenadines | EN
  • Sint Maarten | EN / NL
  • USA | EN / ES
  • Venezuela | ES / EN
  • Virgin Islands UK | EN
  • Virgin Islands US | EN
  • Australia | EN
  • Bangladesh | EN
  • Hong Kong SAR | ZH / EN
  • India | EN
  • Indonesia | EN
  • Japan | JA / EN
  • Kazakhstan | EN
  • Korea | EN
  • Kyrgyzstan | EN
  • Macao | EN / ZH
  • Malaysia | EN
  • Mongolia | EN
  • Myanmar | EN
  • New Zealand | EN
  • Philippines | EN
  • PR China | ZH / EN
  • Singapore | EN
  • Sri Lanka | EN
  • Tadzhikistan | EN
  • Taiwan | EN
  • Thailand | EN
  • Turkmenistan | EN
  • Uzbekistan | EN
  • Vietnam | EN
  • Afghanistan | EN
  • Algeria | FR / EN
  • Bahrain | EN
  • Benin | EN / FR
  • Botswana | EN
  • Burkina Faso | EN / FR
  • Egypt | EN / FR
  • Ghana | EN
  • Guinea | EN / FR
  • Guinea-Bissau | EN / PT / ES
  • Iran | EN
  • Iraq | EN
  • Israel | EN
  • Ivory Coast | FR / EN
  • Jordan | EN
  • Kenya | EN / FR
  • Kuwait | EN
  • Lebanon | EN
  • Lesotho | EN
  • Liberia | EN
  • Libya | EN
  • Malawi | EN
  • Mali | EN / FR
  • Morocco | FR / EN
  • Mozambique | EN
  • Namibia | EN
  • Oman | EN
  • Pakistan | EN
  • Qatar | EN
  • Saudi Arabia | EN
  • Senegal | EN / FR
  • Sierra Leone | EN
  • South Africa | EN / NL
  • Sudan | EN
  • Swaziland | EN
  • Syria | EN
  • Tanzania | EN
  • Togo | EN / FR
  • Tunisia | FR / EN
  • U.A.E | EN
  • Yemen | EN
  • Zambia | EN
  • Zimbabwe | EN

LE 5000 DF

  • Easy to integrate into existing air systems
  • Suitable for recycling air
  • Simple and safe fixture options
  • No integrated power electronics 

The latest generation of double-flange air heaters is specially designed to be used in hot-air recirculation mode. Depending on the air inlet and air outlet temperature, a massive amount of energy can be saved by "recycling" hot-air. On the inlet side, the device can easily tolerate temperatures up to 150°C / 302°F.

Technical Data

Details LE 5000 DF - 3 x 400 V / 4.5 kW + +

Article No. *117.551*

Attribute Unit Value
Voltage V~ 3 x 400
Power W 4500
Min. air volume(68°F) scfm - 4.5 kW 10.9
Max. air outlet temperature °F 1292
Max. air inlet temperature °F 302
Max. ambient temperature °F 212
Size (L x ∅) inch 7.25 × 4.57
Weight lbs 5.7
Conformity mark CE Certification
Protection class I Protection Class I
Details LE 5000 DF - 3 x 400 V / 7.5 kW + +
Details LE 5000 DF - 3 x 230 V / 8 kW + +

Scope of delivery

 

Additional Products and Accessories

Details General accessories

Flanges

152.905 Outlet Flange for Pipe 60_3 152.905 Outlet Flange for Pipe 60_3
152.905 Outlet Flange LE 5000 DF Ø 5.64/2.39 in x 0.12 i + More
152.441 Gasket Inlet HT 5000 DF 152.441 Gasket Inlet HT 5000 DF
152.441 Gasket HT 5000 DF Inlet (1 pc.) + More
152.372 Outlet Flange DF60 152.372 Outlet Flange DF60
152.372 Outlet Flange LE 50000 DF Ø 2.44 in + More
152.443 Gasket_Outlet_HT5000DF 152.443 Gasket_Outlet_HT5000DF
152.443 Gasket HT 5000 DF Outlet (1 pc.) + More
152.371 Inlet Flange DF60 152.371 Inlet Flange DF60
152.371 Inlet Flange LE 5000 DF Ø 2.36 in + More

Air hose and Adaptor

152.522 Adapter Outlet_62_92 152.522 Adapter Outlet_62_92
152.522 Adapter Ø 2.44 in (inner) to Ø 3.62 in (outer) + More
152.520 Adapter Inlet_60_90 152.520 Adapter Inlet_60_90
152.520 Adapter Ø 2.36 in (inner) to Ø 3.54 in (outer) + More

Item added to watchlist