The electric, double-flange air heater LE 10000 DF is ideally suited for integration into air-duct systems. The inlet air temperature can reach up to 150 °C (302 °F) and the flow of outlet air can be heated to 650 °C (1202 °F).
Technical Data
Metric
Imperial
Phases
3x
Current
8 - 25 A
Voltage
400 - 480 V
Power
5500 - 17000 W
Max. air outlet temperature
650 °C
Min. airflow
Required minimum air volume at 100% heating power and an air inlet temperature of 20°C / 68°F
420 - 1300 l/min
Max. air inlet temperature
150 °C
Max. ambient temperature
100 °C
Overheating protection
No
Max. inlet pressure
100 kPa
Display
No
Additionally sealed
No; Yes
Length
167 mm
Device diameter
146 mm
Weight
3.4 - 4.5 kg
Power cable length
5 m
Approvals
CE; EAC; UKCA; cURus
Protection class
I
Highlights
Efficient air heater
Available capacity up to 17 kW
Compact and easy to integrate
Can be run with an ambient temperature up to 100 °C (212 °F)
Gaskets and additional flanges available as accessories